<?xml version='1.0'?>
<!DOCTYPE art SYSTEM 'http://www.biomedcentral.com/xml/article.dtd'>
<art><ui>1556-276X-6-220</ui><ji>1556-276X</ji><fm>
<dochead>Nano Express</dochead>
<bibl>
<title>
<p>Pool boiling of water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids on horizontal smooth tubes</p>
</title>
<aug>
<au ca="yes" id="A1"><snm>Cieslinski</snm><mi>T</mi><fnm>Janusz</fnm><insr iid="I1"/><email>jcieslin@pg.gda.pl</email></au>
<au id="A2"><snm>Kaczmarczyk</snm><mi>Z</mi><fnm>Tomasz</fnm><insr iid="I1"/><email>tomasz_kaczmarczyk@interia.eu</email></au>
</aug>
<insg>
<ins id="I1"><p>Department of Ecoengineering and Process Apparatus, Gdansk University of Technology, Narutowicza 11/12, 80-233 Gdansk, Poland</p></ins>
</insg>
<source>Nanoscale Research Letters</source>
<issn>1556-276X</issn>
<pubdate>2011</pubdate>
<volume>6</volume>
<issue>1</issue>
<fpage>220</fpage>
<url>http://www.nanoscalereslett.com/content/6/1/220</url>
<xrefbib><pubidlist><pubid idtype="pmpid">21711741</pubid><pubid idtype="doi">10.1186/1556-276X-6-220</pubid></pubidlist></xrefbib>
</bibl>
<history><rec><date><day>31</day><month>10</month><year>2010</year></date></rec><acc><date><day>15</day><month>3</month><year>2011</year></date></acc><pub><date><day>15</day><month>3</month><year>2011</year></date></pub></history>
<cpyrt><year>2011</year><collab>Cieslinski and Kaczmarczyk; licensee Springer.</collab><note>This is an Open Access article distributed under the terms of the Creative Commons Attribution License (<url>http://creativecommons.org/licenses/by/2.0</url>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</note></cpyrt>
<abs>
<sec>
<st>
<p>Abstract</p>
</st>
<p>Experimental investigation of heat transfer during pool boiling of two nanofluids, i.e., water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu has been carried out. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight. The horizontal smooth copper and stainless steel tubes having 10 mm OD and 0.6 mm wall thickness formed test heater. The experiments have been performed to establish the influence of nanofluids concentration as well as tube surface material on heat transfer characteristics at atmospheric pressure. The results indicate that independent of concentration nanoparticle material (Al<sub>2</sub>O<sub>3 </sub>and Cu) has almost no influence on heat transfer coefficient while boiling of water-Al<sub>2</sub>O<sub>3 </sub>or water-Cu nanofluids on smooth copper tube. It seems that heater material did not affect the boiling heat transfer in 0.1 wt.% water-Cu nanofluid, nevertheless independent of concentration, distinctly higher heat transfer coefficient was recorded for stainless steel tube than for copper tube for the same heat flux density.</p>
</sec>
</abs>
</fm><meta>
<classifications>
<classification id="Nanofluids" subtype="theme_series_title" type="BMC">Nanofluids</classification>
<classification id="Nanofluids" subtype="theme_series_editor" type="BMC">Yogesh Jaluria, Liqiu Wang, Stephen Choi and Oronzio Manca</classification>
</classifications>
</meta><bdy>
<sec>
<st>
<p>Introduction</p>
</st>
<p>Recent advances in nanotechnology have allowed development of a new category of liquids termed nanofluids, which was first used by a group in Argonne National Laboratory USA <abbrgrp>
<abbr bid="B1">1</abbr>
</abbrgrp> to describe liquid suspensions containing nanoparticles with thermal conductivities, orders of magnitudes higher than the base liquids, and with sizes significantly smaller than 100 nm. The augment of thermal conductivity could provide a basis for an enormous innovation for heat transfer intensification, which is pertinent to a number of industrial sectors including transportation, power generation, micro-manufacturing, chemical and metallurgical industries, as well as heating, cooling, ventilation, and air-conditioning industry. Literature findings regarding pool boiling of nanofluids can be summarized as follows.</p>
<p>Li et al. <abbrgrp>
<abbr bid="B2">2</abbr>
</abbrgrp> studied boiling of water-CuO nanofluids of different concentrations (0.05% and 0.2% by weight) on copper plate. They observed deterioration of heat transfer as compared to the base fluid and attributed this fact to the sedimentation of nanoparticles which leads to the changing of radius of cavity, contact angle, and superheat layer thickness.</p>
<p>You et al. <abbrgrp>
<abbr bid="B3">3</abbr>
</abbrgrp> reported that independent of the concentration of the nanoparticles (0.001 to 0.05 g/l) nucleate boiling heat transfer coefficients for water-Al<sub>2</sub>O<sub>3 </sub>nanofluid while boiling on plate appeared to be the same as for base fluid. They also found that the size of bubbles increased with addition of nanoparticles to water.</p>
<p>Das et al. <abbrgrp>
<abbr bid="B4">4</abbr>
</abbrgrp> conducted an investigation on the pool boiling of water-Al<sub>2</sub>O<sub>3 </sub>nanofluids on a horizontal tubular heater having a diameter of 20 mm with different surface roughness at atmospheric pressure. It was found that the boiling heat transfer of nanoparticle-suspensions was deteriorated compared to that of pure water. Compared with pure water, surface roughness of the heating surface could also greatly affect the nucleation superheat. The subsidence of nanoparticles was considered as the main reason for the increase of the superheat.</p>
<p>Vassallo et al. <abbrgrp>
<abbr bid="B5">5</abbr>
</abbrgrp> carried out an experiment of water-SiO<sub>2 </sub>nanofluids boiling on a horizontal NiCr wire at atmospheric pressure. No appreciable differences in the boiling heat transfer were found for the heat flux less than the CHF.</p>
<p>Bang and Chang <abbrgrp>
<abbr bid="B6">6</abbr>
</abbrgrp> conducted an experimental investigation on the pool boiling of water-Al<sub>2</sub>O<sub>3 </sub>nanofluids on a plain plate at atmospheric pressure. The concentration of nanoparticles was 0.5%, 1%, 2%, and 4% by volume. It was found that the boiling curves were shifted right - towards higher wall superheats. The deterioration became worse as nanoparticle concentration increased and was related to the change of the heating surface characteristics by the deposition of nanoparticles on the heating surface.</p>
<p>Wen and Ding <abbrgrp>
<abbr bid="B7">7</abbr>
</abbrgrp> studied boiling of water-Al<sub>2</sub>O<sub>3 </sub>nanofluids on a stainless steel disc with 150 mm in diameter at atmospheric pressure. Contrary to the Bang and Chang's work <abbrgrp>
<abbr bid="B6">6</abbr>
</abbrgrp>, heat transfer enhancement has been recorded. Possible explanation of this controversy is lower concentration of nanoparticles used (0.32%).</p>
<p>Shi et al. <abbrgrp>
<abbr bid="B8">8</abbr>
</abbrgrp> carried out experiments with boiling of water-Al<sub>2</sub>O<sub>3 </sub>nanofluid and Fe-water nanofluid on horizontal, copper plate with 60 mm in diameter. The concentration of nanoparticles was 0.1%, 1%, and 2% by volume. Generally, the augmentation and deterioration of heat transfer was observed for water-Fe and water-Al<sub>2</sub>O<sub>3 </sub>nanofluids, respectively.</p>
<p>Nguyen et al. <abbrgrp>
<abbr bid="B9">9</abbr>
</abbrgrp> investigated boiling of water-Al<sub>2</sub>O<sub>3 </sub>nanofluid on chrome-plated, very smooth face of copper block of a 100 mm diameter. The concentration of nanoparticles was 0.5%, 1%, and 2% by volume. In general, it was observed that for a given wall superheat, the heat flux considerably decreased with the increase of the particle concentration. Furthermore, for sufficiently high wall superheat, the heat flux tended to become nearly constant.</p>
<p>Coursey and Kim J. <abbrgrp>
<abbr bid="B10">10</abbr>
</abbrgrp> showed that even if the Al<sub>2</sub>O<sub>3 </sub>nanoparticle concentration was increased by over two orders of magnitude, no enhancement or degradation of heat transfer was observed during boiling of ethanol-based nanofluids on glass or gold surface. It was attributed to the highly wetting nature of ethanol. For ethanol-Al<sub>2</sub>O<sub>3 </sub>nanofluids and copper surfaces, the nucleate boiling was improved with increasing nanoparticle concentration.</p>
<p>Liu and Liao <abbrgrp>
<abbr bid="B11">11</abbr>
</abbrgrp> examined nanofluids, i.e., mixture of base fluid (water and alcohol), the nanoparticles (CuO and SiO<sub>2</sub>) and the surfactant (SDBS), and nanoparticles-suspensions consisted of the base liquid and nanoparticles during pool boiling on the face of copper bar having 20 mm diameter. The boiling characteristics of the nanofluids and nanoparticles- suspensions are poorer compared with that of the base fluids.</p>
<p>Narayan et al. <abbrgrp>
<abbr bid="B12">12</abbr>
</abbrgrp> studied influence of tube orientation on pool boiling heat transfer of water-Al<sub>2</sub>O<sub>3 </sub>nanofluids from a smooth tube of diameter 33 mm inclined at 0&#176;, 45&#176;, and 90&#176;. They found that horizontal orientation gave maximum heat transfer and the boiling performance deteriorated with increase in nanoparticle concentration (0.25%, 1%, and 2% by weight).</p>
<p>Lotfi and Shafii <abbrgrp>
<abbr bid="B13">13</abbr>
</abbrgrp> performed transient quenching experiments with silver sphere 10 mm diameter immersed in water-Ag and water-TiO<sub>2 </sub>nanofluids. It was established that the quenching process was more rapid in pure water than in nanofluids and the cooling time was inversely proportional to the nanoparticle mass concentration (0.5%, 1%, 2%, and 4% - Al<sub>2</sub>O<sub>3 </sub>and 0.125%, 0.255, 0.5%, and 1% - TiO<sub>2</sub>).</p>
<p>Trisaksri and Wongwises <abbrgrp>
<abbr bid="B14">14</abbr>
</abbrgrp> tested R141b-TiO<sub>2 </sub>nanofluids while boiling on horizontal copper cylinder 28.5 mm diameter. They discovered that adding a small amount of nanoparticles did not affect the boiling heat transfer, but addition of TiO<sub>2 </sub>nanoparticles at 0.03% and 0.05% by volume deteriorated the boiling heat transfer. Moreover, the boiling heat transfer coefficient decreased with increasing particle volume concentrations, especially at higher heat flux.</p>
<p>Kathiravan et al. <abbrgrp>
<abbr bid="B15">15</abbr>
</abbrgrp> investigated boiling of water-Cu and water-Cu-SDS (9 wt.%) nanofluids on a 300 mm square stainless steel plate. They revealed that copper nanoparticles caused a decrease in boiling heat transfer coefficient for water as base liquid. The heat transfer coefficient decreased with increase of the concentration of nanoparticles (0.25%, 0.5%, and 1% by weight) for both water-Cu and water-Cu-SDS nanofluids.</p>
<p>Suriyawong and Wongwises <abbrgrp>
<abbr bid="B16">16</abbr>
</abbrgrp> studied boiling of water-TiO<sub>2 </sub>nanofluids on horizontal circular plates made from copper and aluminium with different roughness (0.2 and 4 &#956;m). The concentration of nanoparticles was very low: 0.00005%, 0.0001%, 0.0005%, 0.005%, and 0.01% by volume. For copper plate with nanofluid's concentrations more than 0.0001%, the heat transfer coefficient was found to be less than that of the base fluid at both levels of surface roughness. On the other hand, for aluminium surfaces the heat transfer coefficient was found to be less than that of base fluid at every level of nanofluids concentration and surface roughness.</p>
<p>Ahmed and Hamed <abbrgrp>
<abbr bid="B17">17</abbr>
</abbrgrp> performed experiments with boiling of water-Al<sub>2</sub>O<sub>3 </sub>on a face of copper block of 25.4 mm diameter. Nanofluids at 0.01%, 0.1%, and 0.5% by volume concentrations were prepared at a neutral pH of 6.5 and an acidic pH of 5. Ultrasonic vibration and electrostatic stabilization were used to prepare nanofluids. It was found that concentration increase either reduced or had no effect on heat transfer coefficient. Enhancement of heat transfer coefficient was achieved only at low nanofluid concentration (0.01%) and the nanofluid at a pH of 6.5.</p>
<p>Recently, Kwark et al. <abbrgrp>
<abbr bid="B18">18</abbr>
</abbrgrp> pointed out the transient characteristics of water-Al<sub>2</sub>O<sub>3 </sub>nanofluid boiling on horizontal copper plate. The longer a heater is subjected to nanofluid boiling process, the thicker the nanoparticle coating generated on its surface. The thickness of this nanoparticle coating can then dictate boiling heat transfer coefficient.</p>
<p>The currently available experimental data on boiling heat transfer of nanofluids are still limited. Additionally, conflicting results as far as effect of nanoparticles on the pool boiling heat transfer performance have been reported <abbrgrp>
<abbr bid="B19">19</abbr>
<abbr bid="B20">20</abbr>
</abbrgrp>. As suggested in <abbrgrp>
<abbr bid="B21">21</abbr>
</abbrgrp>, further detailed investigations are necessary to understand the phenomena of boiling of nanofluids. In particular experiments are lacking on the effects of nanoparticles material and heating surface material on boiling heat transfer from horizontal smooth tubes. As a consequence, the main aim of the present study was to obtain boiling characteristics, i.e., boiling curves and heat transfer coefficients for water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids of different concentrations for copper and stainless steel tubes.</p>
</sec>
<sec>
<st>
<p>Experimental</p>
</st>
<sec>
<st>
<p>Experimental set-up</p>
</st>
<p>Figure <figr fid="F1">1</figr> shows a schematic diagram of the experimental apparatus. The test chamber consisted of a cubical vessel made of stainless steel with inside dimensions of 150 &#215; 150 &#215; 250 mm. The horizontal copper and stainless steel tubes having 10 mm OD and 0.6 mm wall thickness formed test heater. The effective length of the test tube was 100 mm. The stainless steel tube was finished with emery paper 400 (<it>R</it>
<sub>a </sub>= 0.08 &#956;m) and copper tube was polished with abrasive compound (R<sub>a </sub>= 0.12 &#956;m). The test tube was cantilever-mounted from the back wall of the test chamber to permit visualization. A resistance cartridge heater was inserted into the test tube to generate heat flux from an electrical power supply. The power supply was adjusted by an electrical transformer. Great care must be exercised with the cartridge heater and temperature measuring instrumentation to ensure good accuracy of the measurement of the inside temperature of the heating cylinder <abbrgrp>
<abbr bid="B22">22</abbr>
</abbrgrp>. In the present study, inside the tube, a copper sleeve with 12 grooves at the outside surface to locate the thermocouples was inserted. The copper sleeve was divided into three equal parts, which were separated by three Teflon, 4 mm long, rings. Twelve K-type thermocouples for surface temperature measurements were installed in the grooves. The ends of the thermocouples were placed in the grooves in the middle of the Teflon ring in order to avoid the influence of the heater on the reading from the thermocouples. The detailed geometry of the test tube is shown in Figure <figr fid="F2">2</figr>. The wall temperature <it>t</it>
<sub>w </sub>was calculated from the formula <abbrgrp>
<abbr bid="B23">23</abbr>
</abbrgrp>
</p>
<fig id="F1"><title><p>Figure 1</p></title><caption><p>Scheme of the experimental rig</p></caption><text>
   <p><b>Scheme of the experimental rig</b>.</p>
</text><graphic file="1556-276X-6-220-1"/></fig>
<fig id="F2"><title><p>Figure 2</p></title><caption><p>Details of the test section</p></caption><text>
   <p><b>Details of the test section</b>. 1 - heating surface, 2 - cartridge heater, 3 - Teflon ring, 4 - copper sleeve, 5 - thermocouples, 6 - insulating cap, 7 - thermoconductive paste.</p>
</text><graphic file="1556-276X-6-220-2"/></fig>
<p>
<display-formula id="M1">
<graphic file="1556-276X-6-220-i1.gif"/>
</display-formula>
</p>
<p>where <it>U </it>and <it>I </it>are cartridge heater voltage drop and current, respectively, <it>D<sub>o</sub>/D<sub>i </sub>
</it>is the outside to inside diameter ratio, <it>L </it>is an active length of a tube, <it>&#955; </it>is a thermal conductivity of a tube material (copper or stainless steel) and <it>t<sub>i </sub>
</it>was calculated as the arithmetic mean of 12 measured inside wall temperatures. The liquid level was maintained at ca. 15 mm above the centerline of the test tube at saturated state.</p>
</sec>
<sec>
<st>
<p>Preparation and characterization of the tested nanofluids</p>
</st>
<p>In the present study, Al<sub>2</sub>O<sub>3 </sub>an Cu were used as nanoparticles while distilled, deionized water was used as a base fluid. Nanofluids with different concentrations were prepared for the experiments. Nanoparticles of the required amount and base fluid were mixed together. Alumina (Al<sub>2</sub>O<sub>3</sub>) nanoparticles, of spherical form have diameter from 5 to 250 nm; their mean diameter was estimated to be 47 nm according to the deliverer (Sigma-Aldrich Co., Poznan, Poland). Copper nanoparticles, of spherical form have diameter from 7 to 257 nm; their mean diameter was estimated to be 48 nm according to the deliverer (Sigma-Aldrich Co., Poznan, Poland). The alumina and copper particle size distributions are shown in Figures <figr fid="F3">3</figr> and <figr fid="F4">4</figr>, respectively. In the powder state, the nanoparticles form loose agglomerates of micrometer size as shown by transmission electron microscopy (TEM) - Figures <figr fid="F5">5</figr> and <figr fid="F6">6</figr>. However, it has been observed that the agglomerates breakdown to a considerable extent to produce smaller size particles and agglomerates when dispersed in water.</p>
<fig id="F3"><title><p>Figure 3</p></title><caption><p>Particle size distribution of the Al<sub>2</sub>O<sub>3 </sub>nano-powder</p></caption><text>
   <p><b>Particle size distribution of the Al<sub>2</sub>O<sub>3 </sub>nano-powder</b>.</p>
</text><graphic file="1556-276X-6-220-3"/></fig>
<fig id="F4"><title><p>Figure 4</p></title><caption><p>Particle size distribution of the Cu nano-powder</p></caption><text>
   <p><b>Particle size distribution of the Cu nano-powder</b>.</p>
</text><graphic file="1556-276X-6-220-4"/></fig>
<fig id="F5"><title><p>Figure 5</p></title><caption><p>TEM of agglomerated nano-aluminium oxide powder</p></caption><text>
   <p><b>TEM of agglomerated nano-aluminium oxide powder</b>.</p>
</text><graphic file="1556-276X-6-220-5"/></fig>
<fig id="F6"><title><p>Figure 6</p></title><caption><p>TEM of agglomerated nano-copper powder</p></caption><text>
   <p><b>TEM of agglomerated nano-copper powder</b>.</p>
</text><graphic file="1556-276X-6-220-6"/></fig>
<p>Dispersants were not used to stabilize the suspension. Ultrasonic vibration was used for 4-5 h in order to stabilize the dispersion of the nanoparticles. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight.</p>
<p>Figures <figr fid="F7">7</figr> and <figr fid="F8">8</figr> display photographs of the tested water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids, respectively.</p>
<fig id="F7"><title><p>Figure 7</p></title><caption><p>Photographs of the water-Al<sub>2</sub>O<sub>3 </sub>nanofluids</p></caption><text>
   <p><b>Photographs of the water-Al<sub>2</sub>O<sub>3 </sub>nanofluids</b>.</p>
</text><graphic file="1556-276X-6-220-7"/></fig>
<fig id="F8"><title><p>Figure 8</p></title><caption><p>Photographs of the water-Cu nanofluids</p></caption><text>
   <p><b>Photographs of the water-Cu nanofluids</b>.</p>
</text><graphic file="1556-276X-6-220-8"/></fig>
<p>The thermal conductivity of the nanofluids was measured using transient hot-wire method (KD2 Pro by Decagon Device Inc.). The results for measurements at ambient temperature range between 18 and 20&#176;C are shown in Figure <figr fid="F9">9</figr>. Each data point is an average value of six measurements and the measurement error ranges within &#177; 5%. It can be seen in Figure <figr fid="F9">9</figr> that the effective thermal conductivity of nanofluids increases considerably against mass concentration, and an enhancement of approximately 10% and 90% are achieved at a particle concentration of 1% by weight for water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids, respectively. Reasonable agreement between present data and Wen and Ding <abbrgrp>
<abbr bid="B7">7</abbr>
</abbrgrp> results for water-Al<sub>2</sub>O<sub>3 </sub>nanofluids can be observed. It is difficult to compare present data of thermal conductivity of water-Cu nanofluids with selected published results because of big scatter of literature data <abbrgrp>
<abbr bid="B24">24</abbr>
</abbrgrp>.</p>
<fig id="F9"><title><p>Figure 9</p></title><caption><p>Effective thermal conductivity of water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids at ambient temperature and various concentrations</p></caption><text>
   <p><b>Effective thermal conductivity of water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids at ambient temperature and various concentrations</b>.</p>
</text><graphic file="1556-276X-6-220-9"/></fig>
</sec>
<sec>
<st>
<p>Experimental procedure</p>
</st>
<p>In a typical experiment, before the test begins, a vacuum pump was used to evacuate the accumulated air from the vessel. Nanofluid at a preset concentration was charged and then preheated to the saturated temperature by auxiliary heater. Next, the cartridge heater was switched on. Measurement was first performed at the lowest power input. Data were collected by increasing the heat flux by small increments. Experiments were performed at atmospheric pressure. Each data point was taken at steady state, the condition of steady state being defined as a variation in the thermocouple outputs of less than 0.001 mV during the 3 min. It generally took about 15 min to achieve steady conditions after the power level was changed.</p>
<p>In order to ensure consistent surface state after each test, the boiling surface was prepared in the same manner, i.e., the stainless steel tube was finished with emery paper 400 and copper tube was polished with abrasive compound, next the test tube was placed in an ultrasonic cleaner for 1 h. Finally, the boiling surface was cleaned by water jet.</p>
</sec>
<sec>
<st>
<p>Uncertainty estimation</p>
</st>
<p>The uncertainties of the measured and calculated parameters are estimated by mean-square method. Because heat flux density was calculated from the formula</p>
<p>
<display-formula id="M2">
<graphic file="1556-276X-6-220-i2.gif"/>
</display-formula>
</p>
<p>the experimental uncertainty of heat flux density was estimated as follows:</p>
<p>
<display-formula id="M3">
<graphic file="1556-276X-6-220-i3.gif"/>
</display-formula>
</p>
<p>Where the absolute measurement errors of the electrical power &#916;<it>P</it>
<sub>max</sub>, outside tube diameter &#916;<it>D</it>
<sub>o </sub>and active length of a tube &#916;<it>L </it>are 10 W, 0.02 mm, and 0.2 mm, respectively. So, the maximum overall experimental limits of error for heat flux density extended from &#177; 1.3% for maximum heat flux density up to &#177; 1.2% for minimum heat flux density.</p>
<p>The experimental uncertainty for the average heat transfer coefficient is calculated as</p>
<p>
<display-formula id="M4">
<graphic file="1556-276X-6-220-i4.gif"/>
</display-formula>
</p>
<p>where the absolute measurement error of the wall superheat, &#948;T, estimated from the systematic error analysis equals &#177; 0.2 K. The maximum error for average heat transfer coefficient was estimated to &#177; 2.3%.</p>
</sec>
</sec>
<sec>
<st>
<p>Results</p>
</st>
<p>Investigation of nucleate saturated pool boiling heat transfer on the outside of smooth horizontal tubes submerged in water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids has been carried out. The measurements were performed at atmospheric pressure and nanoparticles concentration of 0.01%, 0.1%, and 1% by weight.</p>
<sec>
<st>
<p>Comparison of present results with literature data</p>
</st>
<p>In order to validate the apparatus as well as experimental procedure, the present data for distilled water at subatmospheric pressure were compared with those predicted by Cooper correlation <abbrgrp>
<abbr bid="B25">25</abbr>
</abbrgrp>
</p>
<p>
<display-formula id="M1A">
<graphic file="1556-276X-6-220-i5.gif"/>
</display-formula>
</p>
<p>and present results for atmospheric pressure have been compared with the experimental data by Esawy et al. <abbrgrp>
<abbr bid="B26">26</abbr>
</abbrgrp> recorded for distilled water boiling on a smooth horizontal stainless steel tube of almost the same diameter (12.7 mm) heated by a cartridge heater. Figure <figr fid="F10">10</figr> shows comparison of present experimental data with Cooper correlation taking heat flux density as abscissa and heat transfer coefficient as ordinate for the pool boiling of distilled water on horizontal stainless steel smooth tube. The experimental data for the boiling of distilled water are found to be in reasonable agreement with those predicted by Cooper correlation (within a band error &#177; 4.5%) as well as those obtained experimentally by Esawy et al. (within a band error &#177; 2%).</p>
<fig id="F10"><title><p>Figure 10</p></title><caption><p>Variation of present results with Cooper correlation <abbrgrp><abbr bid="B25">25</abbr></abbrgrp> and Esawy et al</p></caption><text>
   <p><b>Variation of present results with Cooper correlation </b><abbrgrp><abbr bid="B25">25</abbr></abbrgrp><b>and Esawy et al</b>. experimental data <abbrgrp><abbr bid="B26">26</abbr></abbrgrp>.</p>
</text><graphic file="1556-276X-6-220-10"/></fig>
</sec>
<sec>
<st>
<p>Effect of nanoparticle material</p>
</st>
<p>Figures <figr fid="F11">11</figr>, <figr fid="F12">12</figr>, <figr fid="F13">13</figr>, and, <figr fid="F14">14</figr> display influence of nanoparticle material on heat transfer during boiling of water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids on smooth copper and stainless steel tubes. Independent of concentration (0.1% and 1%), nanoparticle material (Al<sub>2</sub>O<sub>3 </sub>and Cu) has almost no influence when boiling of nanofluid water-Al<sub>2</sub>O<sub>3 </sub>or water-Cu takes place on smooth copper tube - Figures <figr fid="F11">11</figr> and <figr fid="F13">13</figr>. Moreover, the adding of nanoparticles degrades heat transfer performance while boiling of water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids on copper smooth tube. For stainless steel tube and lower concentration tested (0.1%) - Figure <figr fid="F12">12</figr>, higher heat flux density was obtained for water-Al<sub>2</sub>O<sub>3 </sub>nanofluid than for water-Cu nanofluid. Water-Cu nanofluid displays slight superiority over water-Al<sub>2</sub>O<sub>3 </sub>nanofluid - with the same 1% concentration of nanoparticles, while boiling on smooth stainless steel tube and heat flux density above 40 kW/m<sup>2 </sup>- Figure <figr fid="F14">14</figr>.</p>
<fig id="F11"><title><p>Figure 11</p></title><caption><p>Boiling curves of smooth copper tube in water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids with 0.1% concentration</p></caption><text>
   <p><b>Boiling curves of smooth copper tube in water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids with 0.1% concentration</b>.</p>
</text><graphic file="1556-276X-6-220-11"/></fig>
<fig id="F12"><title><p>Figure 12</p></title><caption><p>Boiling curves of smooth stainless steel tube in water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids with 0.1% concentration</p></caption><text>
   <p><b>Boiling curves of smooth stainless steel tube in water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids with 0.1% concentration</b>.</p>
</text><graphic file="1556-276X-6-220-12"/></fig>
<fig id="F13"><title><p>Figure 13</p></title><caption><p>Boiling curves of smooth copper tube in water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids with 1% concentration</p></caption><text>
   <p><b>Boiling curves of smooth copper tube in water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids with 1% concentration</b>.</p>
</text><graphic file="1556-276X-6-220-13"/></fig>
<fig id="F14"><title><p>Figure 14</p></title><caption><p>Boiling curves of smooth stainless steel tube in water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids with 1% concentration</p></caption><text>
   <p><b>Boiling curves of smooth stainless steel tube in water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids with 1% concentration</b>.</p>
</text><graphic file="1556-276X-6-220-14"/></fig>
</sec>
<sec>
<st>
<p>Effect of nanofluid concentration</p>
</st>
<p>As an example, Figures <figr fid="F15">15</figr> and <figr fid="F16">16</figr> illustrate influence of nanoparticle concentration on heat transfer during boiling on smooth copper tube. Contrary to stainless steel tube experiments - Figures <figr fid="F12">12</figr> and <figr fid="F14">14</figr>, the adding of copper as well as Al<sub>2</sub>O<sub>3 </sub>nanoparticles deteriorates pool boiling heat transfer, shifting the boiling curve to the right. The higher concentration of nanoparticles was the lower heat transfer coefficient got for the same wall superheat.</p>
<fig id="F15"><title><p>Figure 15</p></title><caption><p>Boiling curves of copper tube in water-Cu nanofluid</p></caption><text>
   <p><b>Boiling curves of copper tube in water-Cu nanofluid</b>.</p>
</text><graphic file="1556-276X-6-220-15"/></fig>
<fig id="F16"><title><p>Figure 16</p></title><caption><p>Boiling curves of copper tube in water-Al<sub>2</sub>O<sub>3 </sub>nanofluid</p></caption><text>
   <p><b>Boiling curves of copper tube in water-Al<sub>2</sub>O<sub>3 </sub>nanofluid</b>.</p>
</text><graphic file="1556-276X-6-220-16"/></fig>
</sec>
<sec>
<st>
<p>Effect of tube material</p>
</st>
<p>Figures <figr fid="F17">17</figr>, <figr fid="F18">18</figr>, <figr fid="F19">19</figr>, <figr fid="F20">20</figr>, <figr fid="F21">21</figr>, and <figr fid="F22">22</figr> show influence of heating surface material (tube material) on heat transfer while boiling of water-Al<sub>2</sub>O<sub>3 </sub>or water-Cu nanofluids of different concentrations. Figures <figr fid="F17">17</figr> and <figr fid="F18">18</figr> illustrate boiling curves of smooth stainless steel and copper tubes in water-Al<sub>2</sub>O<sub>3 </sub>nanofluid with 0.01% and 1% nanoparticle concentrations, respectively. Independent of concentration (0.01% and 1%) distinctly higher heat transfer coefficient was recorded for stainless steel tube - Figures <figr fid="F19">19</figr> and <figr fid="F20">20</figr>, respectively. Figures <figr fid="F21">21</figr> and <figr fid="F22">22</figr> illustrate heat transfer coefficient against heat flux density for smooth stainless steel and copper tubes in water-Cu nanofluid with 0.1% and 1% nanoparticle concentrations, respectively. It seems that surface material does not affect the boiling heat transfer in 0.1% water-Cu nanofluid - Figure <figr fid="F21">21</figr>, but for 1% nanoparticle concentration, again like for water-Al<sub>2</sub>O<sub>3 </sub>nanofluid (Figure <figr fid="F17">17</figr>) distinctly higher heat transfer coefficient was recorded for stainless steel tube - Figure <figr fid="F22">22</figr>.</p>
<fig id="F17"><title><p>Figure 17</p></title><caption><p>Boiling curves of water-Al<sub>2</sub>O<sub>3 </sub>(0.01%) nanofluid</p></caption><text>
   <p><b>Boiling curves of water-Al<sub>2</sub>O<sub>3 </sub>(0.01%) nanofluid</b>.</p>
</text><graphic file="1556-276X-6-220-17"/></fig>
<fig id="F18"><title><p>Figure 18</p></title><caption><p>Boiling curves of water-Al<sub>2</sub>O<sub>3 </sub>(1%) nanofluid</p></caption><text>
   <p><b>Boiling curves of water-Al<sub>2</sub>O<sub>3 </sub>(1%) nanofluid</b>.</p>
</text><graphic file="1556-276X-6-220-18"/></fig>
<fig id="F19"><title><p>Figure 19</p></title><caption><p>Heat transfer coefficient during boiling of water-Al<sub>2</sub>O<sub>3 </sub>(0.01%) nanofluid</p></caption><text>
   <p><b>Heat transfer coefficient during boiling of water-Al<sub>2</sub>O<sub>3 </sub>(0.01%) nanofluid</b>.</p>
</text><graphic file="1556-276X-6-220-19"/></fig>
<fig id="F20"><title><p>Figure 20</p></title><caption><p>Heat transfer coefficient during boiling of water-Al<sub>2</sub>O<sub>3 </sub>(1%) nanofluid</p></caption><text>
   <p><b>Heat transfer coefficient during boiling of water-Al<sub>2</sub>O<sub>3 </sub>(1%) nanofluid</b>.</p>
</text><graphic file="1556-276X-6-220-20"/></fig>
<fig id="F21"><title><p>Figure 21</p></title><caption><p>Heat transfer coefficient during boiling of water-Cu (0.1%) nanofluid</p></caption><text>
   <p><b>Heat transfer coefficient during boiling of water-Cu (0.1%) nanofluid</b>.</p>
</text><graphic file="1556-276X-6-220-21"/></fig>
<fig id="F22"><title><p>Figure 22</p></title><caption><p>Heat transfer coefficient during boiling of water-Cu (1%) nanofluid</p></caption><text>
   <p><b>Heat transfer coefficient during boiling of water-Cu (1%) nanofluid</b>.</p>
</text><graphic file="1556-276X-6-220-22"/></fig>
</sec>
</sec>
<sec>
<st>
<p>Conclusions</p>
</st>
<p>Independent of the concentrations tested (0.01%, 0.1%, and 1% by weight) nanoparticle material (Al<sub>2</sub>O<sub>3 </sub>and Cu) has almost no influence while boiling of water-Al<sub>2</sub>O<sub>3 </sub>or water-Cu nanofluids on smooth copper tube.</p>
<p>Contrary to stainless steel tube experiments, the adding of copper as well as Al<sub>2</sub>O<sub>3 </sub>nanoparticles deteriorates pool boiling heat transfer on copper smooth tubes. The higher concentration of nanoparticles was the lower heat transfer coefficient got for the same wall superheat.</p>
<p>Independent of concentration distinctly higher heat transfer coefficient was recorded for stainless steel tube than for copper tube for the same heat flux density. It seems that surface material does not affect the boiling heat transfer in 0.1% water-Cu nanofluid.</p>
<p>A thin solid coating (detected by eye) was observed on copper tubes after tests with water-Al<sub>2</sub>O<sub>3 </sub>and water-Cu nanofluids. The higher concentration of the nanoparticles was the thicker coating was recorded at the end of testing.</p>
</sec>
<sec>
<st>
<p>Competing interests</p>
</st>
<p>The authors declare that they have no competing interests.</p>
</sec>
<sec>
<st>
<p>Authors' contributions</p>
</st>
<p>JTC conceived of the study, carried out the literature review, drafted the manuscript and participated in the design and coordination of the study and discussion of the results. TZK conducted the experiments, prepared all figures and participated in the discussion of the results. Both authors read and approved the final manuscript.</p>
</sec>
</bdy><bm>
<ack>
<sec>
<st>
<p>Acknowledgements</p>
</st>
<p>This work was sponsored by the Ministry of Research and Higher Education, Grant No. N N512 374435.</p>
</sec>
</ack>
<refgrp><bibl id="B1"><title><p>Enhancing thermal conductivity of fluids with nanoparticles</p></title><aug><au><snm>Choi</snm><fnm>S</fnm></au></aug><source>Developments and Applications of Non-Newtonian Flows, ASME, FED-Vol. 231/MD-Vol. 66</source><pubdate>1995</pubdate><fpage>99</fpage><lpage>105</lpage></bibl><bibl id="B2"><title><p>Experimental investigations on boiling of nano-particle suspensions</p></title><aug><au><snm>Li</snm><fnm>CH</fnm></au><au><snm>Wang</snm><fnm>BX</fnm></au><au><snm>Peng</snm><fnm>XF</fnm></au></aug><source>Proc 5th International Conference Boiling Heat Transfer, Montego Bay, Jamaica</source><pubdate>2003</pubdate></bibl><bibl id="B3"><title><p>Effect of nanoparticles on critical heat flux of water in pool boiling heat transfer</p></title><aug><au><snm>You</snm><fnm>M</fnm></au><au><snm>Kim</snm><fnm>JH</fnm></au><au><snm>Kim</snm><fnm>KH</fnm></au></aug><source>Applied Physics Letters</source><pubdate>2003</pubdate><volume>83</volume><fpage>3374</fpage><lpage>3376</lpage><xrefbib><pubid idtype="doi">10.1063/1.1619206</pubid></xrefbib></bibl><bibl id="B4"><title><p>Pool boiling characteristics of nano-fluids</p></title><aug><au><snm>Das</snm><fnm>SK</fnm></au><au><snm>Putra</snm><fnm>N</fnm></au><au><snm>Roetzel</snm><fnm>W</fnm></au></aug><source>Int J Heat and Mass Transfer</source><pubdate>2003</pubdate><volume>46</volume><fpage>851</fpage><lpage>862</lpage><xrefbib><pubid idtype="doi">10.1016/S0017-9310(02)00348-4</pubid></xrefbib></bibl><bibl id="B5"><title><p>Pool boiling heat transfer experiments in silica-water nano-fluids</p></title><aug><au><snm>Vassallo</snm><fnm>P</fnm></au><au><snm>Kumar</snm><fnm>R</fnm></au><au><snm>Amico</snm><fnm>S</fnm></au></aug><source>Int J Heat and Mass Transfer</source><pubdate>2004</pubdate><volume>47</volume><fpage>407</fpage><lpage>411</lpage><xrefbib><pubid idtype="doi">10.1016/S0017-9310(03)00361-2</pubid></xrefbib></bibl><bibl id="B6"><title><p>Boiling heat transfer performance and phenomena of Al<sub>2</sub>O<sub>3 </sub>- water nano-fluids from a plain surface in a pool</p></title><aug><au><snm>Bang</snm><fnm>IC</fnm></au><au><snm>Chang</snm><fnm>SH</fnm></au></aug><source>Int J Heat and Mass Transfer</source><pubdate>2005</pubdate><volume>48</volume><fpage>2407</fpage><lpage>2419</lpage><xrefbib><pubid idtype="doi">10.1016/j.ijheatmasstransfer.2004.12.047</pubid></xrefbib></bibl><bibl id="B7"><title><p>Experimental investigation into the boiling heat transfer of aqueous based &#947;-alumina nanofluids</p></title><aug><au><snm>Wen</snm><fnm>D</fnm></au><au><snm>Ding</snm><fnm>Y</fnm></au></aug><source>J Nanoparticles Research</source><pubdate>2005</pubdate><volume>7</volume><fpage>265</fpage><lpage>274</lpage><xrefbib><pubid idtype="doi">10.1007/s11051-005-3478-9</pubid></xrefbib></bibl><bibl id="B8"><title><p>Experimental study of pool boiling heat transfer for nanoparticle suspensions on a plate surface</p></title><aug><au><snm>Shi</snm><fnm>MH</fnm></au><au><snm>Shuai</snm><fnm>MQ</fnm></au><au><snm>Lai</snm><fnm>YE</fnm></au><au><snm>Li</snm><fnm>YQ</fnm></au><au><snm>Xuan</snm><fnm>M</fnm></au></aug><source>13th International Heat Transfer Conference, Sydney, 2006, paper BOI-06 (CD-ROM)</source></bibl><bibl id="B9"><title><p>Pool boiling characteristics of water Al<sub>2</sub>O<sub>3 </sub>nanofluid</p></title><aug><au><snm>Nguyen</snm><fnm>CT</fnm></au><au><snm>Galanis</snm><fnm>N</fnm></au><au><snm>Roy</snm><fnm>G</fnm></au><au><snm>Divoux</snm><fnm>S</fnm></au><au><snm>Gilbert</snm><fnm>D</fnm></au></aug><source>13th International Heat Transfer Conference, Sydney, 2006, NAN-02 (CD-ROM)</source></bibl><bibl id="B10"><title><p>Nanofluid boiling: the effect of surface wettability</p></title><aug><au><snm>Coursey</snm><fnm>JS</fnm></au><au><snm>Kim</snm><fnm>J</fnm></au></aug><source>Int J Heat Fluid Flow</source><pubdate>2008</pubdate><volume>29</volume><fpage>1577</fpage><lpage>1585</lpage><xrefbib><pubid idtype="doi">10.1016/j.ijheatfluidflow.2008.07.004</pubid></xrefbib></bibl><bibl id="B11"><title><p>Sorption and agglutination phenomenon of nanofluids on a plain heating surface during pool boiling</p></title><aug><au><snm>Liu</snm><fnm>Z</fnm></au><au><snm>Liao</snm><fnm>L</fnm></au></aug><source>Int J Heat and Mass Transfer</source><pubdate>2005</pubdate><volume>48</volume><fpage>2407</fpage><lpage>2419</lpage><xrefbib><pubid idtype="doi">10.1016/j.ijheatmasstransfer.2004.12.047</pubid></xrefbib></bibl><bibl id="B12"><title><p>Effect of surface orientation on pool boiling heat transfer of nanoparticle suspensions</p></title><aug><au><snm>Narayan</snm><fnm>GP</fnm></au><au><snm>Anoop</snm><fnm>KB</fnm></au><au><snm>Sateesh</snm><fnm>G</fnm></au><au><snm>Das</snm><fnm>SK</fnm></au></aug><source>Int J Multiphase Flow</source><pubdate>2008</pubdate><volume>34</volume><fpage>145</fpage><lpage>160</lpage><xrefbib><pubid idtype="doi">10.1016/j.ijmultiphaseflow.2007.08.004</pubid></xrefbib></bibl><bibl id="B13"><title><p>Boiling heat transfer on a high temperature silver sphere in nanofluid</p></title><aug><au><snm>Lotfi</snm><fnm>H</fnm></au><au><snm>Shafii</snm><fnm>MB</fnm></au></aug><source>Int J Thermal Sc</source><pubdate>2009</pubdate><volume>48</volume><fpage>2215</fpage><lpage>2220</lpage><xrefbib><pubid idtype="doi">10.1016/j.ijthermalsci.2009.04.009</pubid></xrefbib></bibl><bibl id="B14"><title><p>Nucleate pool boiling heat transfer of TiO<sub>2</sub>-R141b nanofluids</p></title><aug><au><snm>Trisaksri</snm><fnm>V</fnm></au><au><snm>Wongwises</snm><fnm>S</fnm></au></aug><source>Int J Heat and Mass Transfer</source><pubdate>2009</pubdate><volume>52</volume><fpage>1582</fpage><lpage>1588</lpage><xrefbib><pubid idtype="doi">10.1016/j.ijheatmasstransfer.2008.07.041</pubid></xrefbib></bibl><bibl id="B15"><title><p>Preparation and pool boiling characteristics of copper nanofluids over a flat plate heater</p></title><aug><au><snm>Kathiravan</snm><fnm>R</fnm></au><au><snm>Kumar</snm><fnm>R</fnm></au><au><snm>Gupta</snm><fnm>A</fnm></au><au><snm>Chandra</snm><fnm>R</fnm></au></aug><source>Int J Heat and Mass Transfer</source><pubdate>2010</pubdate><volume>53</volume><fpage>1673</fpage><lpage>1681</lpage><xrefbib><pubid idtype="doi">10.1016/j.ijheatmasstransfer.2010.01.022</pubid></xrefbib></bibl><bibl id="B16"><title><p>Nucleate pool boiling heat transfer characteristics of TiO<sub>2</sub>-water nanofluids at very low concentrations</p></title><aug><au><snm>Suriyawong</snm><fnm>A</fnm></au><au><snm>Wongwises</snm><fnm>S</fnm></au></aug><source>ETFS</source><pubdate>2010</pubdate><volume>34</volume><fpage>992</fpage><lpage>999</lpage></bibl><bibl id="B17"><title><p>The effect of experimental techniques on the pool boiling of nanofluids</p></title><aug><au><snm>Ahmed</snm><fnm>O</fnm></au><au><snm>Hamed</snm><fnm>MS</fnm></au></aug><source>7th International Conference On Multiphase Flow, ICMF 2010, Tampa, Fl USA</source><pubdate>2010</pubdate></bibl><bibl id="B18"><title><p>Pool boiling characteristics of low concentration nanofluids</p></title><aug><au><snm>Kwark</snm><fnm>SM</fnm></au><au><snm>Kumar</snm><fnm>R</fnm></au><au><snm>Moreno</snm><fnm>G</fnm></au><au><snm>Yoo</snm><fnm>J</fnm></au><au><snm>You</snm><fnm>SM</fnm></au></aug><source>Int J Heat and Mass Transfer</source><pubdate>2010</pubdate><volume>53</volume><fpage>972</fpage><lpage>981</lpage><xrefbib><pubid idtype="doi">10.1016/j.ijheatmasstransfer.2009.11.018</pubid></xrefbib></bibl><bibl id="B19"><title><p>Pool boiling of nanofluids: Comprehensive review of existing data and limited new data</p></title><aug><au><snm>Taylor</snm><fnm>RA</fnm></au><au><snm>Phelan</snm><fnm>PE</fnm></au></aug><source>Int J Heat and Mass Transfer</source><pubdate>2009</pubdate><volume>52</volume><fpage>5339</fpage><lpage>5347</lpage><xrefbib><pubid idtype="doi">10.1016/j.ijheatmasstransfer.2009.06.040</pubid></xrefbib></bibl><bibl id="B20"><title><p>Enhancement of heat transfer using nanofluids - An overview</p></title><aug><au><snm>Godson</snm><fnm>L</fnm></au><au><snm>Raja</snm><fnm>B</fnm></au><au><snm>Lal</snm><fnm>DM</fnm></au><au><snm>Wongwises</snm><fnm>S</fnm></au></aug><source>Renewable and Sustainable energy Reviews</source><pubdate>2010</pubdate><volume>14</volume><fpage>629</fpage><lpage>641</lpage><xrefbib><pubid idtype="doi">10.1016/j.rser.2009.10.004</pubid></xrefbib></bibl><bibl id="B21"><title><p>Heat transfer characteristics of nanofluids: a review</p></title><aug><au><snm>Wang</snm><fnm>XQ</fnm></au><au><snm>Mujumdar</snm><fnm>AS</fnm></au></aug><source>Int J Thermal Sc</source><pubdate>2007</pubdate><volume>46</volume><fpage>1</fpage><lpage>19</lpage><xrefbib><pubid idtype="doi">10.1016/j.ijthermalsci.2006.06.010</pubid></xrefbib></bibl><bibl id="B22"><title><p>Nucleate boiling characteristics of R-113 in small tube bundle</p></title><aug><au><snm>Marto</snm><fnm>PJ</fnm></au><au><snm>Anderson</snm><fnm>CL</fnm></au></aug><source>Transactions ASME J Heat Transfer</source><pubdate>1992</pubdate><volume>114</volume><fpage>425</fpage><lpage>433</lpage><xrefbib><pubid idtype="doi">10.1115/1.2911291</pubid></xrefbib></bibl><bibl id="B23"><title><p>Pool boiling of R-22, R124 and R-134a on a plain tube</p></title><aug><au><snm>Chiou</snm><fnm>ChB</fnm></au><au><snm>Lu</snm><fnm>DCh</fnm></au><au><snm>Wang</snm><fnm>ChCh</fnm></au></aug><source>Int J Heat Mass Transfer</source><pubdate>1997</pubdate><volume>40</volume><issue>7</issue><fpage>1657</fpage><lpage>1666</lpage><xrefbib><pubid idtype="doi">10.1016/S0017-9310(96)00239-6</pubid></xrefbib></bibl><bibl id="B24"><title><p>Nanofluids for thermal transport</p></title><aug><au><snm>Keblinski</snm><fnm>P</fnm></au><au><snm>Eastman</snm><fnm>JA</fnm></au><au><snm>Cahill</snm><fnm>DG</fnm></au></aug><source>Materials Today</source><pubdate>2005</pubdate><volume>8</volume><issue>6</issue><fpage>36</fpage><lpage>44</lpage><xrefbib><pubid idtype="doi">10.1016/S1369-7021(05)70936-6</pubid></xrefbib></bibl><bibl id="B25"><title><p>Heat flow in saturated nucleate pool boiling - a wide-ranging examination using reduced properties</p></title><aug><au><snm>Cooper</snm><fnm>MG</fnm></au></aug><source>Advances in Heat Transfer</source><pubdate>1984</pubdate><volume>16</volume><fpage>157</fpage><lpage>239</lpage><xrefbib><pubid idtype="doi">full_text</pubid></xrefbib></bibl><bibl id="B26"><title><p>Crystallization fouling of finned tubes during pool boiling: effect of fin density</p></title><aug><au><snm>Esawy</snm><fnm>M</fnm></au><au><snm>Malayeri</snm><fnm>MR</fnm></au><au><snm>M&#252;ller-Steinhagen</snm><fnm>H</fnm></au></aug><source>Proceedings of International Conference on Heat Exchanger Fouling and Cleaning VIII - 2009. June 14-19, 2009, Schladming, Austria</source><editor>M&#252;ller-Steinhagen H, Malayeri MR, Watkinson AP</editor><pubdate>2009</pubdate></bibl></refgrp>