Resolution: standard / high Figure 2.
Pool boiling curve for DI water and nanofluids tests systematically discussed in this
work. Approximate uncertainty in measurement of q" and ΔTs are both 2%. The ONB is at approximately the same superheat (~7°C) for all experiments
(i.e., water and nanofluid ONB is very similar). ONB, onset of nucleate boiling.
Gerardi et al. Nanoscale Research Letters 2011 6:232 doi:10.1186/1556-276X-6-232 |